Avelec

for use with fuel or oil Basic Sensor

Telemetry Adapter Module.

General:
•  Operating temperatures up to 120°C.
•  Input from remote Basic Sensor.
•  Output Suitable for connection to in-vehicle Logger inputs and Telemetry inputs.
•  Simultaneous connection to panel readout. (optional)
•  User selectable damping to eliminate surging.
•  High speed Low level warning - for fast response to sudden fluid loss.
•  Telemetry System compatible output - 1 to 5 volt DC or 0.5 to 4.5 Volt DC.
 Instant pushbutton calibration - no voltmeter required.
•  Fully encapsulated electronics.
Back to Top

Electrical:
•  Power consumption:   10.5 to 20 VDC, 50mA typ. (see notes.)
•  Operating temperature range:   -20 to +120°C.
•  Output:   1 to 5 volts or 0.5 to 4.5 volts linear with depth in 56 steps.  Optional output to panel instrument available.
•  Response:   Two levels of damping user selected with one connector pin - full to empty in approx 4 secs or                        approx 100 secs.  (Typical values - dependent on sensor length and fluid properties)
•  Low level warning:   5 volt fast response output at user settable level.
•  Electrical connectors:   Deutsch AS Autosport & optional BNC for simultaneous panel readout.
•  Notes:   a) Use only power supplies with voltage excursions inside specified limits.   
                b)   Supply current varies with supply voltage.
Back to Top

Mechanical:
•  Housing Dimensions:  W - 100mm, D - 50mm, H - 25mm.
•  Material:   Diecast Aluminium.
Back to Top

Specifications:
•  General
•  Electrical
•  Mechanical